RoboteQ Dual Channel Digital Motor Controller AX500 Manuel d'utilisateur Page 118

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 154
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 117
Serial (RS-232) Controls and Operation
118 AX500 Motor Controller Users Manual Version 1.9b. June 1, 2007
RC Joystick or Analog Deadband
Address: ^06
Access: Read/Write
Effective: After Reset or ^FF
This parameter configures the amount of joystick or potentiometer motion can take place
around the center position without power being applied to the motors.
Exponentiation on Channel 1 and Channel 2
Address: ^08 - Channel 1
^09 - Channel 2
Access: Read/Write
Effective: Instantly
This parameter configures the transfer curve that is applied the input command.
Left/Right Adjust
Address: ^0B
Access: Read/Write
Effective: After Reset or ^FF
Bit Definition See pages
7:0 Values are for Joystick deadband
0 = no deadband
1 = 8%
(2) = 16% (default)
3 = 24%
4 = 32%
5 = 40%
6 = 46%
7 = 54%
page 88
or
page 97
Bit Definition See pages
7:0 (0) = Linear (no exponentiation - default)
1 = strong exponential
2 = normal exponential
3 = normal logarithmic
4 = strong logarithmic
page 89
Vue de la page 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 153 154

Commentaires sur ces manuels

Pas de commentaire